D1VW UK.INDD RH 05.08.2011
2-7
Directional Control Valve
Series D1VW
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
2
Characteristics
General
Design Directional spool valve
Actuation Solenoid
Nominal size DIN NG06 / CETOP 03 / NFPA D03
Mounting interface DIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03
Mounting position unrestricted, preferably horizontal
Ambient temperature [°C] -25...+50
MTTF
D
value [years] 150
Weight [kg] 1.5 (1 solenoid), 2.1 (2 solenoids)
Hydraulic
Max. operating pressure [bar] P, A, B: 350; T: 210 (DC), T: 140 (AC)
Fluid Hydraulic oil in accordance with DIN 51524 / 51525
Fluid temperature [°C] -25 ... +70
Viscosity permitted [cSt] / [mm²/s] 2.8...400
Viscosity recommended [cSt] / [mm²/s] 30...80
Filtration ISO 4406 (1999); 18/16/13 (meet NAS 1638: 7)
Flow max. [l/min] 80 (see shift limits)
Leakage at 50 bar [ml/min] Up to 10 per flow path, depending on spool, up to 15 per flow path for spool type 008 + 009
Static / Dynamic
Step response see table response time
Electrical characteristics
Duty ratio 100% ED; CAUTION: coil temperature up to 150 °C possible
Max. switching frequency [1/h] 15000 (not for soft shift)
Protection class IP 65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Code K J U G Y T
Supply voltage [V] 12 V = 24 V = 98 V = 205 V =
110V at 50Hz/ 230V at 50Hz/
120V at 60Hz 240V at 60Hz
Tolerance supply voltage [%] ±10 ±10 ±10 ±10 ±5 ±5
Current consumption hold [A] 2.72 1.29 0.33 0.15 0.6 / 0.55 0.3 / 0.27
Current consumption in rush [A] 2.72 1.29 0.33 0.15 2.5 / 2.4 1.25 / 1.2
Power consumption hold 32.7 W 31 W 31.9 W 30.2 W 70 / 70 VA 70 / 70 VA
Power consumption in rush 32.7 W 31 W 31.9 W 30.2 W 280 / 290 VA 280 / 290 VA
Solenoid connection Connector as per EN 175301-803, solenoid identification as per ISO 9461 (code W).
Wiring min. [mm²] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended
Technical data
With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.
The NG06 directional control valve series D1VW provides
high functional limits up to 80 l/min in combination with a
very low, energy-saving pressure drop.
A wide variety of spool options allows to design an un-
limited number of hydraulic circuits.
Versions with 8 watt coils, position control, Atex approval,
surface protection and connector variants are shown in
the following chapters.
A B
D1VW UK.INDD RH 05.08.2011
2-8
Directional Control Valve
Series D1VW
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
2
Ordering Code
Directional
control
valve
Wet pin
armature
solenoid,
threaded
in tube
3-chamber
valve
Spool
position
Spool
type
Size
DIN NG06
CETOP 03
NFPA D03
1)
Consider specific spool position.
3 position spools
Code Spool type
a 0 b
001
002
003
004
005
006
007
008
1)
009
1)
010
011
014
015
016
021
022
031
032
034
035
061
081
082
102
204
1)
205
1)
2 position spools
Code Spool type
a b
020
026
030
083
1)
101
208
3 position spools
Code Spool position
C
3 positions.
Spring offset in position “0“.
Operated in position “a“ or “b“.
Standard
Spool type 008,009,
204, 205
E
Operated in
position “a“.
Operated in
position “b“.
2 positions.
Spring offset in position “0“.
F
Spring offset in
position “b“.
Spring offset in
position “a“.
2 positions.
Operated in position “0“.
K
Operated in
position “b“.
Operated in
position “a“.
2 positions.
Spring offset in position “0“.
M
Spring offset in
position “a“.
Spring offset in
position “b“.
2 positions.
Operated in position “0“.
2 position spools
Code Spool position
Standard Spool type 083
B
a
b
A
P
T
B
2 positions.
Spring offset in position “b“.
Operated in position “a“.
D
2 positions.
Operated in position “a“ or “b“.
No center or offset position.
H
a
b
A
P
T
B
2 positions.
Spring offset in position “a“.
Operated in position “b“.
D 1 WV
D1VW UK.INDD RH 05.08.2011
2-9
Directional Control Valve
Series D1VW
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
2
Seals
Solenoid
option
Solenoid
connector as per
EN 175301-803,
without plug
(other connectors
are available for
D1MW Series)
Solenoid
voltage
Further spool types, solenoid voltages and connectors on request.
Ordering Code
Code Seals
N NBR
V FPM
2)
To be used in combination with
rectifier plugs at 120VAC / 230VAC
power supply.
Code Solenoid option
omit
Standard solenoid with
manual override
T without manual override
S2
3)
Soft shift orifice size 0.5 mm.
S3
3)
Soft shift orifice size 0.75 mm.
4N
3)
with lockable manual override
Code Voltage
K 12V =
J 24V =
U
2)
98V =
G
2)
205V =
Y
110V 50Hz /
120V 60Hz
T
230V 50Hz /
240V 60Hz
3)
DC only
Design
series
(not required
for ordering)
W
D1VW UK.INDD RH 05.08.2011
2-10
Directional Control Valve
Series D1VW
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
2
Flow Curve Diagram
Flow curve
Spool
Position “b” Position “a” Position “0”
P-A B-T P-B P-B A-T P-A P-A P-B A-T B-T P-T
001 2 2 2 2
002 1 4 1 4 1 1 5 5 2
003 3 4 3 6 7
004 2 3 2 3 7 7
005 2 2 2 2 12
006 1 4 1 4 7 7
007 3 2 2 2 3 2 7
010 3 3
011 2 2 2 2 14 14
014 3 2 2 2 3 2 7
015 3 6 3 4 7
016 2 2 2 2 12
020B 4 4 2 3
026B 4 4
030B 2 3 1 2
034 4 8 3 3 5 7
035 3 3 4 8 7 5
081 13 13 13 13
082 13 13 13 13
1) 1)
101B 11 10 10 9
102 1 4 1 4 5 5 8 8 6
61 1 3 1 3 3 2
83H 5 2 5 2
104 1 2 5 3 14 14
208 3 2
P-B A-T P-A B-T P-A P-B A-T B-T P-T
008 4 5 4 5 9
009 5 5 6 7 7
83B 5 2 5 2
204 1 3 4 3 7 4 7
205 4 3 1 3 7 4 5
Spool
Position “b” Position “a”
1)
Only for pressure compensation,
no high flow possible.
P-A P-B A-B P-B A-T
021 2 4 4 2
P-A B-T P-A P-B A-B
022 6 2 5 2
2 2
2 2
1
2
3
4
5
6
7
89
13
14
Flow [l/min]
Pressure drop [bar]
0
4
8
12
16
20
0 20 6040 80
24
12
10
11
All characteristic curves measured with HLP46 at 50°C.
D1VW UK.INDD RH 05.08.2011
2-11
Directional Control Valve
Series D1VW
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
2
Flow [l/min]
10 20 30 40 50 60 70 80 900
0
50
100
150
200
250
300
350
Pressure [bar]
082
009,
011,
102
003, 015,
204, 205
010,021,
022
101
0
50
100
150
200
250
300
350
Pressure [bar]
Flow [l/min]
10 20 30 40 50 60 70 80 900
007,
014, 081
005, 008,
016, 020
026
004
002
006, 030
001
004
005, 008,
016, 020
002
Flow [l/min]
10 20 30 40 50 60 70 80 900
0
50
100
150
200
250
300
350
Pressure [bar]
010
005, 016
001,002, 006
026
Flow [l/min]
0
50
100
150
200
250
300
350
Pressure [bar]
10 20 30 40 50 60 70 80 900
082
081
021, 022
003, 004, 015
011
007, 008,
009, 014,
083
020, 030
The diagram below specifies the shift limits for valves with
DC solenoids. Valves with spool position “F” or “M” can
only be operated up to 70% of the limits. The specifica-
tions apply to a viscosity of 40mm
2
/s and balanced flow
conditions. The shift limits can be considerably lower at
unbalanced flow conditions. To avoid flow rates beyond
the shift limits, a plug-in orifice can be inserted in the
P-port.
Valve with standard DC solenoid
Valve with standard AC solenoid
Measured with HLP46 at 50°C, 90% U
nom
and warm solenoids
Measured with HLP46 at 50°C, 95% U
nom
and warm solenoids
Shift Limits
D1VW UK.INDD RH 05.08.2011
2-12
Directional Control Valve
Series D1VW
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
2
300
200
250
100
50
150
350
0 2010 30 40 50 60 70 80
Supply pressure [bar]
Flow [l/min]
001,
004
081,
082
009002
020D
300
200
250
100
50
150
350
0 2010 30 40 50 60 70 80
Supply pressure [bar]
Flow [l/min]
002,
020
030
009,
102
101
001, 004,
081
Response times D1VW Standard and Soft Shift
Step response times were obtained under the following conditions: HLP46 at 50°C with the valve operating at nominal pressure and flow. Published
response times are nominal and may vary with spool, flow, pressure and temperature.
Acceleration for orifice size 0.75, code “S3” (measured against a standard valve)
Response Times
For even softer shifting, the proportional spools 081, 082, 101 and 102 can be used.
Shift limit diagram - Soft shift with 1 DC solenoid
Shift limit diagram - Soft shift with 2 DC solenoid
A B
Measured with HLP46 at 50°C, 90% U
nom
and warm solenoids
Response times
Soft Shift
Orifice size
2 solenoid valve 2 solenoid valve 1 solenoid valve
3 positions 3 positions 2 positions
Code
Center position: Closed Center position: Open
Energize De-energize Energize De-energize Energize De-energize
S2 0.50mm 200 - 750 310 - 650 220 - 400 350 - 750 90 - 350 160 - 500
S3 0.75mm 180 - 300 300 - 400 200 - 350 300 - 500 90 - 350 130 - 350
Standard solenoid Orifice Energize De-energize
Standard DC w/o 45 - 60 20 - 30
Standard AC w/o 13 20
Standard DC with rectifier plug w/o 60 -70 70- 90
The lower value applies to small flow rates and low pressure, the upper value to high flow rates and high pressure
build-in orifice
D1VW UK.INDD RH 05.08.2011
2-13
Directional Control Valve
Series D1VW
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
2
Dimensions
The space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm.
The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.
Surface finish
BK375
4x M5x30
DIN 912 12.9
7.6 Nm
±15%
NBR: SK-D1VW-N-91
FPM: SK-D1VW-V-91
C, D -style Option 4N, with lockable manual override
(available for all styles, DC only)
C, D -style
H, K, M -style
Interface EN 175301-803, DC solenoid
B, E, F -style H, K, M -style
Interface EN 175301-803, AC solenoid
B, E, F -style
Ø9.5
Ø5.5
22
93
91.4
162
46
69
A B
93
46
69
Ø9.5
Ø5.5
22
91.4
226
A B
Ø9.5
Ø5.5
22
119.4
93
190
A B
Ø9.5
22
Ø5.5
84
152
46
69.5
93.5
A B
Ø9.5
22
Ø5.5
84
46
69.5
93.5
211
A B
22
Ø5.5
Ø9.5
127
152
46
69.5
93.5
A B
2-14
2
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
2
Notes